Project Description

Multiplexer

MCL-100

rcl-200s_800
rcl-200s-4_800
rcl-200s-3_800
rcl-200s-2_800
User’s Manual

카메라링크 멀티플렉서는 하나의 영상취득 장비에 여러대의 카메라를 연결하여 선택적으로 대용량 영상데이터를 실시간 초고속으로 전송하도록 설계되었다.     카메라링크 멀티플렉서는 산업용 카메라링크 카메라 2개 또는 4의 신호중 하나를 선택하여 (2:1 또는 4:1) 영상취득장비로 전송할 수 있게 설계되었다.   여기서 카메라와 프레임글래버 양쪽으로 모든 신호 즉 영상신호, RS232,CC1~4의 모든 기능이 능동적으로 선택된다. 사용하지 않는 RS232의 선로 신호는 대기상태가 Full Up으로 자동 설정된다.

The Industrial Camera Link Repeater is designed to extend the transmission distance between the Industrial Camera and the Frame Grabber.  It amplifies the high-capacity, high-precision image signal taken with an industrial camera and transmits it to the imaging acquisition equipment (server PC, etc.) at a real-time high speed without loss.   There are camera link repeaters for short-range copper cables and for long-distance optical cables, and extend transmission distances to simplify machine vision systems and minimize costs.  It provides the best solutions to rapidly changing application industries such as industrial inspection equipment, broadcasting and communication, medical imaging, and security.

Typical Set Up Diagram

Technical  Specification

All of Camera-Link Interface Compliance (Area and Line Scan)

Support Base Configuration (CC1~4, RS232, LVAL, DVAL, FVAL)

Select  Manual(Switch) or Remote(RS232) Camera Funtion

2:1 Selector (Repeater Embadding)

PoCL Bypass

Support Pixel clock from 20 ~ 85MHz

Support PoCL signal bypass

Zero loss and transparent transport

Support Max 256 Kbps  Full duplex RS232

Locking DC power connector (Molex)

  • Machine Vision Applications

  • Robot Vision, Robot Eye

  • Product inspection – PCB, LCD, Wafer

  • Bar code reading and sorting

  • Medical Imaging

  • Port/Harbor cargo container Management

  • Railroad Measurement / inspection

  • Cameras placed in harsh environment – Nuclear plant, Chemical plant, Factory

  • Bridge inspection

  • Military & Defencse Applications

  • Astronomy

  • Computer microscopy

  • Multi-media

Product MCL-100
Pixel Clock Range 20 ~ 85 [MHz]
Supported Camera Configration Base Configuration,  2:1 Selector (Repeater Embadding)
Sync. Signals LVAL, FVAL, DVAL
Camera Control CC1 ~ CC4, RS232
Serial Communication SerTFG, SerTC
Connector Type Camera Link (MDR)
Control Connector Type RS232 / DB9 Female

Operating Temperature 0 ~ 50[℃]
Input Voltage DC 12 ~ 24 [V], Bypass-PoCL
Typical Supply Current @ 12V DC 300 [mA]
Connector Type Molex 53259-0329 Male, DC Jack : DC 005
Weight (Approximate) 150 Gram each module